12" Rewindable Submersible Motors
12" Rewindable Submersible Motors
These 12" rewindable motors, manufactured in ISO 9001 certified facilities, are built for dependable operation in 12" diameter or larger water wells. It is fitted with water lubricated radial and thrust bearings for maintenance-free operation. The motor is filled with a special FES93 fluid, providing frost protection down to -15 ºC storage temperature. A special diaphragm ensures pressure compensation inside the motor.
-
Features & Benefits
- Easy to assemble with double flange
- Cable material according to drinking water regulations (VDE/ACS/KTW approved)
- Sand fighter® SiC seal system for high performance in sand
- High efficiency electrical design for low operation cost
- All motors prefilled and 100% tested
- Max. storage temperature 5°F (-15 °C) to 140 °F (60 °C)
- Design for retrofitable PT100 sensor
- Non contaminating FES 93 filled design
Options
- 80 kN thrust load
- Other voltages
- Y∆ - start (pos. of cables 90°)
- PT 100 temperature sensor (sold separately)
- Special lead lengths available upon request
- 316 SS construction
Technical Specifications
- 12" Three-Phase Motors, 2-Pole, 3600 RPM
- 185-400 kW / 250-536 hp
- 12" flange
- IP 68 protection
- 5 maximum starts per hour
- Vertical and horizontal installation
- Motor Lead in 20 ft. (6 m) length
- 460 V/60 Hz and 575 V/60 Hz standard voltages
- Voltage tolerance (50 Hz): -10% / +6% UN [380-415V = (380-10%) – (415+6%)]
- Voltage tolerance (60 Hz): ±10% UN
- 30 ºC ambient temperature with a minimum cooling flow: v = 0.5 m/s
-
12-Inch Three-Phase Models (2P - 3600 RPM)
PN (kW/HP) UN / f Model No. Digit 1 – 6 Model No. Digit 7 – 10 V Hz DOL Y∆ PE2/PA21 304 316 SS 904 L 185/250 460/380 60/50 265 610 265 710 5021 6021 - 575 60 265 690 265 760 220/300 460/380 60/50 265 611 265 711 575 60 265 691 265 761 250/340 460/380 60/50 265 612 265 712 575 60 265 692 265 762 300/400 460/380 60/50 265 614 265 714 575 60 265 694 265 764 350/470 460/380 60/50 - 265 716 575 60 265 696 265 766 400/536 460/380 60/50 - 265 717 575 60 265 697 265 767 -
Motor Leads
Inner Dim. Outer Dim. Lengths (m/ft) Motor (kW/HP) Qyt. Lead Kit Lead Seal Kit. 380-415 V / 50 Hz 500 V / 50 Hz 1000 V / 50 Hz Ø (mm2) D (mm/in) 460 V / 60 Hz (3 Single Leads) 1X70 20.7/0.82 44002 185-300/250-400 DOL 185-400/250-536 DOL - DOL 1 308 711 100 308 661 120 300-400/400-536 Y∆** 1X35 15.3/0.60 44002 185-250/250-340 Y∆** 185-400/250-536 Y∆** 185-400/250-536 DOL Y∆ 2 DOL 1 308 711 101 308 661 121 Y∆ 2 - NOTE: For this standard PE2/PA motors must additionally ordered the special Tape 700 541 688, is absolutely necessary
- ** For Y∆ motors please order two Lead (sealing) kits
Inner Dimn. Ø (mm²) Outer Dim. D Ø (mm/in) Lengths (m/ft) St. Mod.-Nr. 1G25 13.0/0.51 44069 1 308 053 080 1G35 15.3/0.60 44002 308 056 060 - *Only for 304 SS and 316 SS
Lead Opening Seal Kit Motor (kW/HP) Part No. 250-400/340-536 DOL/Y∆ 308 661 122 - NOTE: Cables are designed for submerged operation; for air operation please consult Franklin Electric
Technical Data
304/316 SS Stator and Rotor PN (kW/HP) Stator (incl. winding and 6 m motor lead) Rotor UN / f DOL PVC DOL PE2/PA Y∆ PVC Y∆ PE2/PA V Hz 185/250 380-415 50 - 327 013 902K - 326 013 952K 176 381 500K 460/380 60/50 220/300 380-415 50 326 639 902K 326 639 952K 176 381 501K 460/380 60/50 250/340 380-415 50 326 639 902K 326 639 952K 176 381 501K 460/380 60/50 300/400 380-415 50 326 640 902K 326 640 952K 176 381 502K 460/380 60/50 350/470 380-415 50 - 326 696 952K 176 381 504K 460/380 60/50 400/536 380-415 50 326 641 952K 176 381 503K 460/380 60/50 Insulation Standard Windings (460 V/60 Hz) PN Model No. Turns Per Coil Wire Dia. Isolation Type Group Conn. Total Wire L (m) Resist. Coil (Ω) Resist. Y∆ Resist. DOL (U1-U2) (Ω) (U1-V1) (Ω) (kW/HP) Winding Kits (mm) 185/250 327013999 6+6+6+6 2.6/3.9 (2GrII) PE2/PA Parallel Delta 794 0.1061 - - 220/300 326639999 5+6+5+6 2.7/4.1 (2GrII) 770 0.0901 250/340 326639999 5+6+5+6 2.7/4.1 (2GrII) 770 0.0901 300/400 326640999 4+5+4+5 3.0/4.5 (2GrII) 720 0.0677 350/470 326696999 4+4+4+5 3.0/4.5 (2GrII) 706 0.0664 400/536 326641999 4+4+4+4 3.3/4.8 (2GrII) 700 0.0536 Insulation Standard Windings (575 V / 60 Hz) PN Model No. Turns Per Coil Wire Dia. Isolation Type Group Conn. Total Wire L (m) Resist. Coil (Ω) Resist. Y∆ Resist. DOL (kW/HP) Winding Kits (mm) (U1-U2) (Ω) (U1-V1) (Ω) 185/250 327535999 7+8+7+8 2.3/3.5 (2GrII) PE2/PA Parallel Delta 1075 0.1694 - - 220/300 326701999 7+7+7+7 2.5/3.8 (2GrII) 1000 0.1338 250/340 326702999 6+7+7+7 2.5/3.8 (2GrII) 924 0.129 300/400 326703999 5+6+5+6 2.7/4.1 (2GrII) 861 0.1021 350/470 326697999 5+5+5+6 2.7/4.1 (2GrII) 856 0.1012 400/536 326704999 5+5+5+5 2.9/4.3 (2GrII) 848 0.0867 Insulation Resistant (20 °C/500 VDC) New Motor w/o Drop Cable 400 > MΩ Used Motor w/o Drop Cable 20 > New Motor w/ Drop Cable 4 > Used Motor w/ Drop Cable 1 -
Spec Sheets